Tipo de Articulo: Artículos Originales

Titulo: Densidad sea volumtrica vertebral obtenida sin fantoma en estudios de rutina de tomografa computarizada de abdomen: correlacin con los valores medidos por densitometra sea areal por rayos X

Title: PHANTOM-LESS VOLUMETRIC VERTEBRAL DENSITY OBTAINED FROM ROUTINE ABDOMINAL CT STUDIES: CORRELATION WITH DATA OBTAINED BY DXA

Actual. Osteol 12(3):180:187, 2016

Autor(es): Haraldo Claus-Hermberg, Silvina De Luca, Fiorella Troncoso, Mara Pa Lozano Bullrich, Magdalena Rey, Silvana Boffa, Mara Josefina Pozzo


Descargar en formato PDF

La densida mineral sea (DMO) por tomografa computarizada cuantitativa (QCT) mide con exactitud y precisin de corto plazo la densidad volumtrica (DMOv) de secciones axiales de los cuerpos vertebrales lumbares valindose de un fantoma de calibracin. Existe evidencia de que la densitometra por TC sin fantoma presenta muy alta correlacin con la DMO por QCT y que es confiable para evaluar la densidad sea vertebral. Apoyndonos en ello, correlacionamos DMO y CMO estimados a partir de estudios de TC con los obtenidos por DXA. Se incluyeron 28 mujeres (edad: 63,410,3 aos, rango: 37-85) que haban realizado una TC de abdomen y previamente una DMO en un lapso previo no mayor de 6 meses. Se midieron: 1) TC: DMOv (promedio integral trabecular + cortical) en UH en un corte axial medio vertebral de 10 mm de espesor y el rea en cm2. Se multiplic la densidad por el rea, obteniendo un valor equivalente al CMO de la seccin (CMO-TC) y 2) DXA: se consideraron la DMOa y CMO en una RI de 10 mm de altura a nivel del centro de la vrtebra L3. Las correlaciones entre los parmetros homlogos obtenidos por ambos mtodos fueron significativas: result superior para CMO [DMOv vs. DMOa r: 0,67 (p=0,005) y CMO-TC vs. CMO-DXA r: 0,75 (p=0,00063)]. El estudio complementa los ya existentes y abre la posibilidad de utilizar estudios de rutina de TC de abdomen para evaluar la densidad sea, para lo cual debern establecerse valores de referencia sexo y edad especficos.

Palabras claves: densidad mineral sea, tomografa computarizada, contenido mineral seo, , densidad volumtrica sin fantoma.

Conventional quantitative computed tomography (QCT) uses a calibration phantom scanned simultaneously with the anatomical region of interest and measures bone density accurately and with short-term high precision. Evidence supports that phantomless volumetric BMD highly correlates with QCT BMD and is a reliable method for assessing bone density of vertebral bodies. Assessment of BMD in routine abdominal CT scans has been investigated in recent years. The aim of the study was to correlate BMD and bone mineral content (BMC) obtained from CT studies with data obtained by DXA. Twenty eight women (age 63.4 10, 3 years old, range: 37-85) who underwent abdominal CT for different reasons and DXA measurements within 6 months were included. A simple manual region of interest (RI) which delineated the edge of the vertebral body was applied to L3.We measured 1) CT: Volumetric integral density (BMDv) -trabecular and cortical bone- of the axial section in Hounsfield units (UH) and area (A) in cm2. Density was multiplied by area to obtain a value equivalent to BMC. 2) DXA: BMD and BMC in a RI of 10 mm height in the middle of L3 All parameters obtained by CT correlated significantly with the corresponding to DXA : BMDv vs BMDa r: 0.67 (p=0.005) y BMC- CT vs BMC-DXA: r :0.75 (p=0.00063). This study complements previous reports and opens the possibility of using routine abdominal CT studies to assess bone density. For that purpose reference values (age and gender) must be established.

Key words: bone mineral density, quantitative computed tomography, bone mineral content, phantom-less volumetric density.

Propietario: Asociacin Argentina de Osteologa y Metabolismo Mineral (AAOMM)
Domicilio legal: 9 de Julio 1324, (2000) Rosario, Santa Fe, Argentina.
Editores responsables: Dra. Luisa Plantalech - Dr. Lucas R. Brun.

Osteologia.org.ar - Todos los derechos reservados AAOMM
Derecho Nacional de Derecho de Autor (Exp N 5289263 - 16/05/2016)
Registro de la Propiedad Intelectual de la Revista online (Exp N = 5316855 - 21/10/2016)